Formulation-Filter

Firma

Text

Kategorie

Schlagwörter

Environmentally-Friendly

Formulation ID: 30/CCSUN20073/02

PhaseMaterial NameEU INCI% Material
A SymEffect™ Varytex (342911) PROPANEDIOL DICAPRYLATE/CAPRATE, TRIISONONANOIN, DIISOPROPYL ADIPATE, CAPRYLIC/CAPRIC TRIGLYCERIDE, STEARYL HEPTANOATE, GLYCERYL OLEATE CITRATE, CETEARYL NONANOATE, STEARYL CAPRYLATE 10.00
Neo Heliopan® Flat (294843) HOMOSALATE, OCTOCRYLENE, BIS-ETHYLHEXYLOXYPHENOL, METHOXYPHENYL TRIAZINE, BUTYL METHOXYDIBENZOYLMETHANE, ETHYLHEXYL SALICYLATE 30.00
SymDecanox™ HA (972276) CAPRYLIC/CAPRIC TRIGLYCERIDE, HYDROXYMETHOXYPHENYL DECANONE 1.00
Edeta® BD DISODIUM EDTA 0.10
Fragrance PARFUM 0.50
Sensocel® 10 CELLULOSE 2.00
Cosphaderm® X Soft XANTHAN GUM 0.30
B
Aqua/Water AQUA 49.45
Bentone™ Hydroclay 2000 HECTORITE 0.80
Avicel® PC 611 MICROCRYSTALLINE CELLULOSE, CELLULOSE GUM 0.80
Glycerin 99.5% GLYCERIN, AQUA 1.00
SymReboot™ L19 (846066) MALTODEXTRIN, LACTOBACILLUS FERMENT 0.50
Hydrolite® 5 green (996442) PENTYLENE GLYCOL 1.50
SymOcide® PH (973949) PHENOXYETHANOL, HYDROXYACETOPHENONE, CAPRYLYL GLYCOL, AQUA 3.00
Dragosine 844033) CARNOSINE 2.00
C Citric Acid 10% Sol. AQUA, CITRIC ACID 0.50


Processing

  1. Phase A: Premix phase A
  2. Phase B: Disperse Avicel® PC 611 and Bentone™ EW in water with an Ultra-Turrax stirrer at 6.000 rpm for 7 minutes.
  3. Add all remain ingredients to the water phase.
  4. Add phase B to phase A and start to homogenize.
  5. The pH value of the finished product should be approx. 6.0 and has to be checked.

Reference

24344 C

In vivo SPF

Measured according to the ISO 24444:2010 “Determination of Sun Protection factor SPF” on a five-subject panel test, the formula has an in-vivo SPF 61.5.

Disclaimer

These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Symrise makes no warranties, either expressed or implied, as to the accuracy or appropriateness of this data. Symrise expressly disclaims any implied warranty of fitness for a particular use. We recommend that prospective users determine for themselves the suitability of Symrise materials and suggestions for any use prior to their adoption. We also recommend that prospective users, as required, obtain approval from appropriate regulatory authorities. Suggestions for uses of our products or the inclusion of descriptive material from patents and the citation of specific patents in this publication should not be understood as recommending the use of our products in violation of any patent or as a permission or licence to use any patent of Symrise. For questions concerning product safety and dangerous substance classification please ask for the Safety Data Sheets of the used Symrise products. 24.02.2021.

Zurück nach oben

Wir nutzen Cookies auf unserer Website. Einige von ihnen sind essenziell für den Betrieb der Seite, während andere uns helfen, diese Website und die Nutzererfahrung zu verbessern (Tracking Cookies). Sie können selbst entscheiden, ob Sie die Cookies zulassen möchten. Bitte beachten Sie, dass bei einer Ablehnung womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen.